Open core: don’t reinvent the wheel — build your fenestration software on ours.

Skip to main content

Glossary & domain overview

The system is dense with fenestration jargon. This glossary gives each term its general
industry meaning so the rest of the manual reads cleanly.

The product — a window or door

A manufactured unit is modelled as a hierarchy, top to bottom:

Term Meaning
Unit / Overall One complete manufactured window or door assembly — the root of a unit’s geometry. Contains one or more facets.
Facet A major design face/section of a unit (e.g. Front, Side). A simple window has one facet; a bay/bow or corner unit has several.
Frame The fixed outer perimeter everything mounts into: Head (top), Sill (bottom), and the two Jambs (verticals).
Opening A hole within a frame, filled by a sash, fixed glass, or further subdivided by mullions.
Mullion A structural bar dividing a frame/opening into multiple openings. Vertical (V) and horizontal (H) mullions follow separate code paths.
Coupler A joining member that couples separate units/openings together. In this app a coupler splits a facet into equal openings.
Transom A horizontal divider/opening above a door or main window.
Sash The framed (often operable) assembly holding the glass inside an opening. A sash leaf is one individual panel; multiple leaves = e.g. a French door.
Operation type How a sash moves: Casement (side-hinged), Awning (top-hinged), Hopper (bottom-hinged), Slider/Glider (horizontal), Single/Double Hung (vertical), Fixed (non-operating).
DLO — Daylight Opening The visible glazed area: the hole light passes through, measured to the inside edge of the glazing bead.
Glazing bead The trim strip retaining the glass; its inner edge defines the DLO.
Glass / Lite A glazed pane/area. “Divided lites” = glass split into multiple visual panes by grids.
Sealed Unit (SU) / IGU Insulated Glass Unit: two or more panes bonded around a spacer with a sealed gas gap.
Spacer The perimeter bar between panes of a sealed unit; its size drives grid cut sizes.
Grid / Muntin / Bar Decorative bars dividing the glass into smaller lights (true-divided, between-glass, or applied).
SUH — Sealed-Unit Height A setback measured down from the top edge of the glass. On a grid template it is a setup value that starts the grid pattern below the sealed-unit top line (see Grids & the SUH setback); as a per-item value it is the top-mullion setback computed for each glass unit and sent to glass suppliers.
Series A product line / extrusion profile system. Pricing and part-selection rules are per series.
Profile An extruded cross-section member (frame/sash/mullion stock).
BOM — Bill of Materials The parts and cut pieces to manufacture the unit.
Cut list / CLF Manufacturing cut output: each profile piece’s length, miter/cut angles, and saw feed direction.
Design Pressure (DP) / Wind load The structural rating a unit must meet for a location (wind-resistance lookups by city).

The business

  • Partner / Supplier / Tenant — a customer company using the system. OpenJanela is multi-tenant: each partner has its own database, resolved at runtime.
  • Order / Job / Line item — an order contains line items; each line item is one configured unit.

Units of measure (important)

Internal dimensions are stored as integers, not decimals:

  • Imperial = 64ths of an inch.
  • Metric = millimetres × 100 (hundredths of a millimetre).

A raw dimension value is therefore not “the number the user typed” — it is converted at the
edges of the system. This convention recurs throughout the Notching chapter.