How Can We Help?
The glass picker offers every sealed unit that (1) fits one of the series’ Glazing Thickness
bands (thickness between From and To — the imperial columns for an imperial series — and the number of
panes, unless Panes is 0), (2) has Display on (the “detailed list” tick-box shows the others), and
(3) if the series is limited to SU families, belongs to one of them. A replacement series uses its own replacement
list. The rules then do the rest: clearances, gas, spacer, beads by thickness. Glass rules:
How to set glass clearances, gas and glass-related parts; optional thickness:
Sealed units with an optional thickness.
Examples
- 7100 (230) Glazing Thickness: 2 panes 46–53/64″, 2 panes 81–87/64″ (target 84),
3 panes 81–87/64″. That gives about 58 units, for exampleSB603/CLEAR3, 2 panes,
47/64″. 3501 uses 99999 / 696969 as “no upper limit”. - Rules around the glass: Sealed Units (38) sets glass supplier and gas; sub-routines 405/406 set spacers by SU type;
beads are chosen by SU thickness: 7100 rule 1219 calls 227 “7100 PW GB”, the 3501 calls 465/265 by option
QSU OA THICK.
Steps
- To offer more or fewer units: Series → Glazing Thickness tab → add or delete bands (From/To in
both units, Panes). - Make sure the sealed unit itself is set up on the Sealed Units screen with thickness in both units, panes and
Display on. - Check the glass rules: bead sub-routines and their SU-thickness tests, spacer, gas and supplier rules. A new
thickness usually needs a matching bead rule, otherwise the item builds without beads or with the wrong ones. - A different glass family may need different glass clearances (glass rules).
- Build an item with the new glass; check glass size, beads, spacer, gas and the Glazing station.
an imperial company uses the imperial ones. Some units in the example data have a wrong metric thickness (73 = 0.73 mm next to
47/64″), so a metric company would not see them. The glazing station rule (38 rule 85, 465 rule 40) routes
everything after it. No screen was found for limiting a series to SU families — ask support if you need it.
Use read_data on the company database, read-only. Replace :series with the id of the series the user names (find it with SELECT id, description FROM series WHERE description LIKE '%7100%'). One statement only, starting with SELECT or WITH, no semicolon, at most 200 rows. The guard rejects these words anywhere, even inside quoted text or aliases: INSERT, UPDATE, DELETE, REPLACE, MERGE, UPSERT, CALL, DO, SET, CREATE, ALTER, DROP, TRUNCATE, GRANT, REVOKE, RENAME, LOCK, UNLOCK, HANDLER, LOAD, EXECUTE, EXEC — so run the recipes as written, with no extra labels. A product is the series plus every sub-routine it calls; the recipes walk that tree. They return numbers, because the company database has no rule-type name tables: translate them with the list below, and answer in shop words.
R10 — the glass list the picker will offer (imperial company; for metric use thickness,
from_thick, to_thick):
SELECT DISTINCT s.id AS su_type_id, s.stockcode, LEFT(s.description, 40) AS description, s.num_of_leaves AS panes,
s.thickness AS thick_mm100, s.thickness_imp AS thick_64ths, s.family_id
FROM su_type s
JOIN series_allowed_su_thick t
ON t.series_id = :series
AND s.thickness_imp BETWEEN t.from_thick_imp AND t.to_thick_imp
AND (t.panes = 0 OR s.num_of_leaves = t.panes)
WHERE s.display = 1
AND (NOT EXISTS (SELECT 1 FROM su_family_by_series f WHERE f.series_id = :series)
OR s.family_id IN (SELECT f.su_family_id FROM su_family_by_series f WHERE f.series_id = :series))
ORDER BY s.num_of_leaves, s.thickness_imp, s.stockcode
LIMIT 200
R7 — the thickness bands:
SELECT t.panes, t.from_thick AS from_mm100, t.to_thick AS to_mm100, t.from_thick_imp AS from_64ths,
t.to_thick_imp AS to_64ths, t.target_thick, t.target_thick_imp,
(SELECT COUNT(*) FROM su_type_by_series b WHERE b.series_id = t.series_id) AS glass_list_rows
FROM series_allowed_su_thick t
WHERE t.series_id = :series
ORDER BY t.panes, t.from_thick
R6 — rules acting on glass and beads (series and sub-routines). On 7100 it gives about 400 rows, mostly
spacer rules in 405/406, so add AND r.ruletype = one type to stay under 200:
WITH RECURSIVE tree(sid) AS (
SELECT :series
UNION
SELECT r.rulevalue FROM tree t
JOIN rules r ON r.series_id = t.sid AND r.ruletype = 9 AND r.active = 1
)
SELECT r.series_id, s.description AS in_series, r.id AS rule_no, r.ruletype, r.level, r.position,
r.rulevalue, r.rulevaluei, r.test, LEFT(r.description, 40) AS description
FROM tree
JOIN rules r ON r.series_id = tree.sid
JOIN series s ON s.id = r.series_id
WHERE r.active = 1
AND r.ruletype IN (4, 21, 24, 25, 26, 30, 43, 44, 80, 93, 94, 103, 104, 400, 401)
AND r.level IN (6, 7, 8, 21)
ORDER BY r.ruletype, r.series_id, r.id
LIMIT 200
Numbers to names. Rule type: 1 Option Choice, 2 Option Auto, 3 Option sub-routine, 4 Clearance, 5 Clearance Matrix, 6 Part, 7 Part Matrix, 8 Profile Matrix, 9 Rule sub-routine (Rule Segment), 10 Comment, 14 production line, 15 station, 19 Warning, 20 Error, 21 glass supplier, 24 SU gas, 25 SU spacer, 43/44 SU thickness, 90 assembly, 92 parent assembly. Level: 1 Overall, 2 Facet, 3 Frame, 4 Sash Type, 5 Sash, 6 Glass, 7 Glazing Bead, 8 DLO, 29 Grids, 31 Coupler, 32 Mullion, 40 Opening. Position: 1 Top, 2 Bottom, 3 Left, 4 Right, 5 Top+Bottom, 6 Left+Right, 7 All Sides, 11 WxH/Area, 13 Perimeter, 26 Unit. End cut: 1 Mitered, 2 Straight, 3 Machined. Test type: 8 Global Option, 9 Shape/M Option, 10 UD Opening (Open/Shape id), 11 Open Class (1 Picture, 2 LH, 3 RH, 4 Top hinged, 5 Fixed sash), 15 SU Type, 17 SU Thick. Sizes: metric columns are mm×100, imperial columns (ending in i or _imp) are 64ths of an inch; an imperial company (series_uom 2) uses the imperial ones.